Welcome: Ningbo Yundahui Trading Co., Ltd.
sales01@ydh-clima.com +8613989669747

YDH.BS.0112

TECHNICAL PARAMETERS OF KFR AIR CONDITIONER
TYPE (m):COASTER
NOMINAL COOLING CAPACITY/HEATING CAPACITY (kw):12/10
TOTAL POWER CONSUMPTION (kw):5
RANGE OF INPUT VOLTAGE(V.DC):300-700VDC
REFRIGERANT/ FILLING QUANTITY(kg):
COMPRESSOR
INPUT POWER(kw):4.0
LUBRICATING OIL:ESTER OIL
SUPPLY VOLTAGE:30~70HZ
Voltage:3PH/220V
EVAPORATOR
TYPE:finned tube type (rifled copper tube, hydrophilic aluminum foil)
EXPANSION VALVE CAPACITY(RT):TCL2.5MW100SAE
FAN
TYPE:CENTRIFGAL TYPE
AIRFLOW (m³/h):2700
CURRENT (A):27A(24VDC)
CONDENSER
TYPE:finned tube type (rifled copper tube, hydrophilic aluminum foil)
FAN
TYPE:AXILAL TYPE
AIRFLOW (m³/h):5400(24V.DC)
CURRENT (A):27A(24V.DC)
Total Weight (Condenser Assembly/Evaporator assembly/Compressor assembly) (kg):80Kg
CONTROL SYSTEM
Panel:WD01
Dimensional/opening size of panel:Opening as per drawing
COMPARTMENT TEMPERATURE (℃):16-33 continuously adjustable
DEFROST TEMPERATURE(℃):Defrosting starts below 2℃, stops at 7Cor higher
AIR FLOW:Non-level or three-level speed control
SAFETY DEVICE
High/low voltage control
switch and compressor
heating protection switch(MPa):
30.0/0.05MPa OFF,Pa>30.0MPa,
Operation pressure, Pa<0.5Mpa
Operation pressure

EMAIL

TECHNICAL PARAMETERS OF KFR AIR CONDITIONER

TYPE (m):COASTER

NOMINAL COOLING CAPACITY/HEATING CAPACITY (kw):12/10

TOTAL POWER CONSUMPTION (kw):5

RANGE OF INPUT VOLTAGE(V.DC):300-700VDC

REFRIGERANT/ FILLING QUANTITY(kg):

COMPRESSOR

INPUT POWER(kw):4.0

LUBRICATING OIL:ESTER OIL

SUPPLY VOLTAGE:30~70HZ

Voltage:3PH/220V

EVAPORATOR

TYPE:finned tube type (rifled copper tube, hydrophilic aluminum foil)

EXPANSION VALVE CAPACITY(RT):TCL2.5MW100SAE

FAN

TYPE:CENTRIFGAL TYPE

AIRFLOW (m³/h):2700

CURRENT (A):27A(24VDC)

CONDENSER

TYPE:finned tube type (rifled copper tube, hydrophilic aluminum foil)

FAN

TYPE:AXILAL TYPE

AIRFLOW (m³/h):5400(24V.DC)

CURRENT (A):27A(24V.DC)

Total Weight (Condenser Assembly/Evaporator assembly/Compressor assembly) (kg):80Kg

CONTROL SYSTEM

Panel:WD01

Dimensional/opening size of panel:Opening as per drawing

COMPARTMENT TEMPERATURE (℃):16-33 continuously adjustable

DEFROST TEMPERATURE(℃):Defrosting starts below 2℃, stops at 7Cor higher

AIR FLOW:Non-level or three-level speed control

SAFETY DEVICE

High/low voltage control 

switch and compressor

heating protection switch(MPa): 

30.0/0.05MPa OFF,Pa>30.0MPa,

Operation pressure, Pa<0.5Mpa

Operation pressure


PREVIOUS:YDH.BS.0111 NEXT:YDH.BS.0113

INQUIRY